ZetaSizer Ultra - Malvern (ZETASIZER)

CONTACT US

Guarantor: Michela Sanna, Ph.D.
Instrument status: Operational Operational
Equipment placement: CEITEC Nano - B1.15
Research group: CF: CEITEC Nano


Description:

The ZetaSizer Ultra from the Malvern company provides the ability to measure the size and zeta potential of particles, molecules or micelles in a liquid medium. The unique features of the ZetaSizer for measurements over a wide concentration range and precise temperature control give reproducible, repeatable and accurate results. This device utilizes Multi-Angle Dynamic Light Scattering (MADLS®) technology for the highest resolution of sizing data.

The ZetaSizer works in the sample temperature range of 0–120 °C. The minimum sample volume is 3 μL for the particle size and 20 μL for the zeta potential measurement. The minimum sample concentration for particle size measurement depends on the technique used, starting from 0.1 mg/mL for Dynamic light scattering (Non-Invasive Back-Scatter) to 1 mg/mL for MALDS, the same concentration as for zeta potential. The size range is 0.3–10 μm for size determination and 3.8 nm–100 um for zeta potential measurement.


Publications:

  • THELAPPURATH, A.; SISKA, Z.; ULLATTIL, S.; SIMONIKOVA, L.; PIZUROVA, N., 2026: Microtron-induced surface defects and phase transformations in anatase TiO2 colloidal nanoparticles. SURFACES AND INTERFACES 80, doi: 10.1016/j.surfin.2025.108199; FULL TEXT
    (RIGAKU3, ZETASIZER, FTIR, KRATOS-XPS, TEM TALOS - IPM)
  • Janů, L.; Souawda, N.; Anand, R.; Duday, D.; Medalová, J.; Collard, D.; Nečas, D.; Polášková, K.; Ryšánek, P.; Thomann, J.-S.; Janůšová, M.; Zajíčková, L., 2026: . INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES 343(P2), doi: 10.1016/j.ijbiomac.2026.150226; FULL TEXT
    (KRATOS-XPS, ZETASIZER, SEE-SYSTEM, LYRA, LEICACOAT-NANO, JASCO)
  • Hashemi, A.; Ezati, M.; Zumberg, I.; Chmelíková, L.; Fohlerová, Z.; Provazník, V., 2025: . RSC ADVANCES 15, p. 16826 - 16844, doi: 10.1039/d5ra02940f; FULL TEXT
    (TITAN, FTIR, ZETASIZER)
  • POLÁKOVÁ, V.; MATULOVÁ, J.; BRTNÍKOVÁ, J.; FOHLEROVÁ, Z.; ŠMERKOVÁ, K.; KAISER, J.; ZIKMUND, T.; PROCHÁZKOVÁ, P.; ŽÍDEK, J.; VOJTOVÁ, L., 2025: In Situ Homogeneous Generation of Copper Nanoparticles in Collagen-Cellulose Freeze-Dried Foams Using Natural Reduction Agents to Enhance Their Stability, Antibacterial Properties, and Cytocompatibility. ACS OMEGA 10(35), p. 39799 - 39813, doi: 10.1021/acsomega.5c03661; FULL TEXT
    (MIRA-STAN, ZETASIZER, LEICACOAT-STAN, micro-CT-L240)
  • TINOCO NAVARRO, L.; CIHLÁŘ, J.; MICHALIČKA, J.; KAŠTYL, J.; ČÁSTKOVÁ, K., 2023: . CATALYSIS LETTERS 2, doi: 10.1007/s10562-023-04489-7; FULL TEXT
    (RIGAKU3, WITEC-RAMAN, FTIR, VERIOS, TITAN, BET-DEGASSER, ZETASIZER, KRATOS-XPS, BET-ANAMET)

Show more publications...